AirTAC X-PPV200830 Electrical Proportional Valve
Product feature
- The internal integration of high-precision sensors effectively improves the control accuracy.
- The pressure prompt function is convenient for field operation.
- Customized field bus interface, more flexible.
- ± 5% high control accuracy.
- 0~0.1MPa/0.5MPa/0.9MPa multiple range options.
- 300L~5000L large range flow output is optional.
- Arrival pressure indication/actual output pressure is displayed in real time.
Ordering code
Specification
Project type | Specific parameters |
Power supply | 24VDC±10%, <6W |
Electrical connection | 4-pin M12A standard (male) |
Protection class | IP65 |
Input signal | 0~5/10V or 0/4~20mA or 4-point switch input or manual |
Output signal | 4~20mA or 1~5V or 1-point switch output |
LED indication | Pressure arrival indication and actual output pressure indication |
Installation position | Any direction |
Housing | Aluminium alloy |
Operating temperature(℃) | 0~50℃ |
Flow (Cv value) | X-PPV10/0.3; X-PPV20/1.5; X-PPV30/5.0 |
Minimum intake pressure | 0.1MPa (15psi) (1bar) higher than the maximum output pressure |
Maximum input pressure | 1.0MPa (145psi) (10bar) (range 0~1bar, maximum input pressure 2bar) |
Output range | 0~0.1MPa, 0~05MPa, 0~0.9MPa |
Fluid | Dry compressed air or bridging gas with filtering accuracy of 5 µ m or less |
Lubrication | No, if used, please use neutral lubricating oil |
Accuracy | ≤±0.5% |
Linearity | ≤1.0% F.S. |
Repeatability | ≤±0.5% F.S. |
Hysteresis | ≤0.5% F.S. |
Wiring
Models
X-PPV20083001, X-PPV20083002, X-PPV20083003, X-PPV20083004.
X-PPV20083011, X-PPV20083012, X-PPV20083013, X-PPV20083014.
X-PPV20083021, X-PPV20083022, X-PPV20083023, X-PPV20083024.
X-PPV20083031, X-PPV20083032, X-PPV20083033, X-PPV20083034.
X-PPV20083041, X-PPV20083042, X-PPV20083043, X-PPV20083044.
Dimensions
Reviews